Hood clamshell
Save time and precision on your non-destructive testing (NDT LT)
The most precise Non-Destructive Test for leak testing on the market
3 min
Implementation time
10-9 mbar.l.s-1
Helium leak rate
Without helium supply
Works in open circuit
Our hood clamshell is a non-destructive leak testing (NDT LT) solution. It enables you to qualify a weld as quickly as possible. In fact, it takes only 3 minutes to seal your weld and obtain the result. The hood clamshell measures a helium leak rate as low as 10-9 mbar·l·s-1. This achieved rate makes our shell the best NDT LT solution on the market in terms of time efficiency and precision.
Our hood clamshell is used in the most demanding leak-tightness applications: nuclear, aerospace, particle accelerators, aeronautics, cryogenics, and more. Our material is specifically designed for non-destructive helium leak testing.
NUCLEAR
AEROSPACE
PARTICLE ACCELERATOR
AERONAUTICS
How the hood clamshell works
Watch the explanatory video of our hood clamshell.
Why use our hood clamshell :
- Isolates the area to be tested
- Direct zone validation
- Easy to set up
- Time saving for NDT
- Small footprint
- Plug & play
Tube to tube
Diameter reduction
Plug
Custom made
The possibilities are endless. We can design hood clamshells NDT for flanges or areas with limited space. For your specific needs, contact us.
Technical datas
- Leak rate : 10-9 mbar.l.s-1
- Vacuum pressure: 10-1 to 10-3 mbar
- NDT time: 3 minutes from implementation to result
- ISO KF 16 or ISO KF 25 connection → Plug and play on mass spectrometers
- From Ø 6mm to Ø 600mm
- Small cross section: 15 to 25mm
- Operates in open circuit: specific validation of a weld
- Helium tracer gas possible but not mandatory
- Tube to tube hood clamshell available : ND8 / 10 / 15 / 20 / 25 / 32 / 40 / 50 / 65 / 80 / 90 / 100 / 125 / 150 / 200 / 250 / 300 / 350 / 450